Liebert CRV - Intelligent, Efficient Precision Cooling for Data Center Equipment

Click here: to request a visit to the Tech Data Solutions Center

Liebert in the Solutions Center

Solutions

This self contained rack sized Liebert CRV cooling solution was added to the 390sf glassed room in our Solution Center to cool the hottest area that we have.  This row-based application was placed between the two hottest racks within the enclosure as our current air conditioning configuration would not suffice.  We have additional sensors throughout the room to report back to the unit so the CRV can adjust airflow and temperatures automatically.

Virtual Dmos:

Flexibility:

  • Horizontal airflow cooling design is suitable for non-raised or raised floors.
  • Air, water, glycol and chilled water systems available.
  • Adjustable airflow baffles maximize cooling to rack equipment, allowing the system to be positioned within the row or at the end of the row.
  • Caster mounted for easy placement.
  • Multiple units communicate with each other to improve system performance and reduce energy consumption.
  • Up to 10 racks per cooling unit may be monitored to improve system performance and report rack temperatures.
  • The iCOM large graphic display allows easy navigation and clear data display.
  • Can be used with SmartAisle containment system.

Availability:

  • Self-adapts to changing conditions to provide 24/7 precision environmental control: cooling, humidity control and air filtration.
  • Liebert iCOM control provides alerts for preventive maintenance before issues occur.
  • Variable capacity Digital Scroll compressor adapts to load and eliminates compressor cycling, greatly increasing compressor life.

Lowest Total Cost of Ownership:

  • Designed for higher return air temperature to maximize cooling capacity.
  • Only front and back access required, resulting in minimized installation and service time.
  • Digital scroll compressor and variable speed EC fans operate efficiently to reduce energy consumption

Ideally Suited For:

  • Small to medium-sized data centers cold/hot aisle configurations.
  • Heat density up to 10 kW/rack without containment.
  • Raised and non-raised floors.
  • Rooms with a low ceiling where air cannot be ducted.
  • SmartAisle containment system.
  • Spot cooling in large data centers.

 

Last update: 08/20/2012 05:41 PM b


IMPORTANT NOTE:
The information contained on this site references products intended for U.S. customers only.

Enjoy your visit!

Support services and website data presented herein and on all subordinate sites are based upon technical information provided by the manufacturers of the relevant products sold by Tech Data. Tech Data believes this information to be accurate; however, Tech Data makes no representations or warranties with respect to the performance of the support services and information, and any and all warranties, whether oral or written, expressed or implied, are hereby expressly disclaimed by Tech Data, including, but not limited to, warranties of merchantability and fitness for a particular purpose.